...
IDS 2025
We are at the world's leading congress "International Dental Show 2025" | 25-29 March
Show More

Venuscon®

Dental Implant System

Merkurhex®

Dental Implant System

Kits & Tools

Surgical Set

Prosthetic Solutions

Abutment | Gingiva Former | Impression Parts

What Have We Achieved So Far?

We began our journey in 2021 with the sale of 20,000 units. By 2022, that figure soared to 120,000 units, marking a remarkable 300% increase. In 2024, our total implant production reached 500,000 units. Looking ahead to 2025, our goal is to achieve sales in the range of 400,000 to 550,000 units, further solidifying our position in both domestic and global markets. This growth trajectory is a direct result of sound strategies, high-quality products, and our commitment to customer satisfaction.

Our Journey

Following four successful years of growth rates surpassing 100%, we anticipate that 2025 will be a pivotal year in strengthening our presence on the global stage. The significant milestones we’ve achieved so far instill confidence in our future aspirations, and the 300% sales increase trend is poised to continue with sustainable growth. By expanding our investments and implementing innovation-driven strategies, we will reinforce our leading position in the industry.

Country
0
Distributor
Sales
0

Global Distributor Network

Thanks to our global dealer network, you can access our business partners and dealers who provide uninterrupted service for the sale of our products.

Our approach

Innovations Shaping the Future

Science and Technology Focus

We aim to facilitate the surgical procedure with the implant systems we have developed in the light of advanced technology and scientific data.

Global Standards

By combining local expertise with global quality standards, we produce products that are used safely in 7 different countries.

Sustainability and Biocompatibility

We offer implants that are both environmentally friendly and safe with high-quality titanium and innovative surface technologies.

We prioritize innovative solutions, reliability and patient satisfaction

VenusCon

Highlights from our YouTube Channel!

28 March 2025

17:28

28 March 2025

17:28

Open Tray | HEX

Code Platform Diameter Gingival Height (H)
SLV 30108 Ø4.0 2.5mm
SLV 30110 Ø4.8 2.5mm

Open Tray | NO-HEX

Code Platform Diameter Gingival Height (H)
SLV 30109 Ø4.0 2.5mm
SLV 30111 Ø4.8 2.5mm

Open Tray Impression Parts are packed with SLV 16002 screw.

Open Tray Screw
SLV 16002
Analog
SLV 30201

ENHANCED RBM SURFACE

All VenusCon Implants were surface roughened with the RBM (Resorbable Blast Media) process. To achieve the desired roughness, the implant is sandblasted with hardened Hydroxyapatite (beta-Tricalcium Phosphate, Alpha Tcp, Ttcp and Calcium Phosphate (CPP) particles and then dissolved from the surface by a defined passivation process. Studies have reported that implant surface roughness of min. RA 1-1.5 μm constitutes the ideal surface. As a result of the surface roughness analyzes performed on Medisolaris products, it was predicted that the RA values were higher than the accepted 1-1.5 μm, which would increase the bone-implant contact. The surface roughness of Medisolaris Dental Implants is realized as RA 2-2.5 μm.

This surface treatment is designed to roughen the implant surface without leaving any residual embedded sand particles or residue on the implant.

This process involves sandblasting the implant surface with Calcium Phosphate material to create a macro topography and then performing the passivation process to remove the embedded Hydroxyapatite Particles from the environment.

Consequently, it results in a greater surface area for Osseointegration, improved attachment properties, increased biological fixation, and a rougher implant surface than conventional acid etching, which maximizes Implant-Bone contact.

As a result of the Edax Analysis performed at Celal Bayar University, no elements that cause biocontamination and negatively affect osseointegration were found.

Thanks to the improved new RBM Surface, excellent values ​​compatible with bone morphology have been achieved, ensuring faster and better osseointegration quality.

8mm

SLM 3208

10mm

SLM 3210

11mm

SLM 3211

12mm

SLM 3212

13mm

SLM 3213

16mm

SLM 3216

6mm

SLM 3706

8mm

SLM 3708

10mm

SLM 3710

11mm

SLM 3711

12mm

SLM 3712

13mm

SLM 3713

16mm

SLM 3716

6mm

SLM 4206

8mm

SLM 4208

10mm

SLM 4210

11mm

SLM 4211

12mm

SLM 4212

13mm

SLM 4213

16mm

SLM 4216

6mm

SLM 4706

8mm

SLM 4708

10mm

SLM 4710

11mm

SLM 4711

12mm

SLM 4712

13mm

SLM 4713

16mm

SLM 4716

6mm

SLM 5206

8mm

SLM 5208

10mm

SLM 5210

11mm

SLM 5211

12mm

SLM 5212

13mm

SLM 5213

16mm

SLM 5216

8mm

SLV 3208

10mm

SLV 3210

11mm

SLV 3211

13mm

SLV 3213

16mm

SLV 3216

6mm

SLV 3706

8mm

SLV 3708

10mm

SLV 3710

11mm

SLV 3711

13mm

SLV 3713

16mm

SLV 3716

6mm

SLV 4306

8mm

SLV 4308

10mm

SLV 4310

11mm

SLV 4311

13mm

SLV 4313

16mm

SLV 4316

6mm

SLV 5006

8mm

SLV 5008

10mm

SLV 5010

11mm

SLV 5011

13mm

SLV 5013

16mm

SLV 5016

Blister Tube

Venuscon® Implants are presented in sterile blister and tube with implant cover screw.

 

Make sure that the safety strip of the tube cover of the Venuscon® Implant in the sterile tube has not been opened before. The Cover on the hanger removed from the tube is removed by pulling in the axial direction. Transfer and Tightening Part is placed in such a way that the index direction and the implant index direction are parallel, and the implant is applied to the opened slot. Transfer and Tightening Part is removed by applying 5Ncm force.

Implant cover screw is removed by applying 5Ncm force with Conic Hex and by pulling in the axial direction.

Packaging & Label

All traceability is ensured by the UTAKSIS ERP program specially prepared for the medical sector, through to the Code and Lot Number on the product labels.

Güneş ışığından uzak tutunuz

Kullanma talimatlarına başvurunuz

Tekrar kullanmayın

Tekrar steril edilemez

Işınlama kullanılarak steril edilmiştir

Uyarı, beraberinde verilen dökümanlara başvurunuz

Sıcaklık aralığı

Ambalaj hasarlı ise kullanmayın

Nem aralığı

Çift steril bariyer sistemi

Sterilization was carried out with Gamma rays in accordance with the standard. Implants are presented in a sterile package, under suitable storage conditions, whose stability is guaranteed for 5 years.

Venuscon® Implants are manufactured with gamma ray resistant materials suitable for medical use, the implants are placed vertically in the Titanium Rings on the hanger. There is a Cover Screw at the bottom of the hanger. It is designed to be taken with a 1.25 Conical HEX Wrench, Implant tubes are placed in heat-sealed transparent Blister and Tyvek in compliance with medical and gamma irradiation standards.

 

It was successfully passed the double-leakage tests with Sealed Tube and Sealed Blister packaging.

Blister Tube

Merkurhex® Implants are presented in sterile blister and tube with implant cover screw.

Make sure that the safety strip of the tube cover of the Merkurhex® Implant in the sterile tube has not been opened before. The Cover on the hanger removed from the tube is removed by pulling in the axial direction. Transfer and Tightening Part is placed in such a way that the index direction and the implant index direction are parallel, and the implant is applied to the opened slot. Transfer and Tightening Part is removed by applying 5Ncm force.

Implant cover screw is removed by applying 5Ncm force with Conic Hex and by pulling in the axial direction.

Packaging & Label

All traceability is ensured by the UTAKSIS ERP program specially prepared for the medical sector, through to the Code and Lot Number on the product labels.

Güneş ışığından uzak tutunuz

Kullanma talimatlarına başvurunuz

Tekrar kullanmayın

Tekrar steril edilemez

Işınlama kullanılarak steril edilmiştir

Uyarı, beraberinde verilen dökümanlara başvurunuz

Sıcaklık aralığı

Ambalaj hasarlı ise kullanmayın

Nem aralığı

Çift steril bariyer sistemi

Sterilization was carried out with Gamma rays in accordance with the standard. Implants are presented in a sterile package, under suitable storage conditions, whose stability is guaranteed for 5 years.

Merkurhex® Implants are manufactured with gamma ray resistant materials suitable for medical use, the implants are placed vertically in the Titanium Rings on the hanger. There is a Cover Screw at the bottom of the hanger. It is designed to be taken with a 1.25 Conical HEX Wrench, Implant tubes are placed in heat-sealed transparent Blister and Tyvek in compliance with medical and gamma irradiation standards.

It was successfully passed the double-leakage tests with Sealed Tube and Sealed Blister packaging.

Straight Abutment | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP201 Ø3.8 1.0mm
SLV NP202 Ø3.8 2.0mm
SLV NP203 Ø3.8 3.0mm
SLV NP204 Ø3.8 4.0mm
SLV NP205 Ø3.8 5.0mm

Straight Abutment | Regular

Code Platform Diameters Gingival Height (H)
SLV RP206 Ø4.7 1.0mm
SLV RP207 Ø4.7 2.0mm
SLV RP208 Ø4.7 3.0mm
SLV RP209 Ø4.7 4.0mm
SLV RP210 Ø4.7 5.0mm

Straight Abutment | Wide

Code Platform Diameters Gingival Height (H)
SLV WP211 Ø5.7 1.0mm
SLV WP212 Ø5.7 2.0mm
SLV WP213 Ø5.7 3.0mm
SLV WP214 Ø5.7 4.0mm
SLV WP215 Ø5.7 5.0mm

15° Angled Abutment | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP251 Ø3.8 1.0mm
SLV NP252 Ø3.8 2.0mm
SLV NP253 Ø3.8 3.0mm
SLV NP254 Ø3.8 4.0mm

15° Angled Abutment | Regular

Code Platform Diameters Gingival Height (H)
SLV RP255 Ø4.7 1.0mm
SLV RP256 Ø4.7 2.0mm
SLV RP257 Ø4.7 3.0mm
SLV RP258 Ø4.7 4.0mm

15° Angled Abutment | Wide

Code Platform Diameters Gingival Height (H)
SLV WP259 Ø5.7 1.0mm
SLV WP260 Ø5.7 2.0mm
SLV WP261 Ø5.7 3.0mm
SLV WP262 Ø5.7 4.0mm

25° Angled Abutment | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP263 Ø3.8 1.0mm
SLV NP264 Ø3.8 2.0mm
SLV NP265 Ø3.8 3.0mm
SLV NP266 Ø3.8 4.0mm

25° Angled Abutment | Regular

Code Platform Diameters Gingival Height (H)
SLV RP267 Ø4.7 1.0mm
SLV RP268 Ø4.7 2.0mm
SLV RP269 Ø4.7 3.0mm
SLV RP270 Ø4.7 4.0mm

25° Angled Abutment | Wide

Code Platform Diameters Gingival Height (H)
SLV WP271 Ø5.7 1.0mm
SLV WP272 Ø5.7 2.0mm
SLV WP273 Ø5.7 3.0mm
SLV WP274 Ø5.7 4.0mm

Anatomic Straight Abutment | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP301 Ø3.8 1.0mm
SLV NP302 Ø3.8 2.0mm
SLV NP303 Ø3.8 3.0mm

Anatomic Straight Abutment | Regular

Code Platform Diameters Gingival Height (H)
SLV RP304 Ø4.7 1.0mm
SLV RP305 Ø4.7 2.0mm
SLV RP306 Ø4.7 3.0mm

Anatomic Straight Abutment | Wide

Code Platform Diameters Gingival Height (H)
SLV WP307 Ø5.7 1.0mm
SLV WP308 Ø5.7 2.0mm
SLV WP309 Ø5.7 3.0mm

Anatomic 15° Straight Abutment | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP351 Ø3.8 1.0mm
SLV NP352 Ø3.8 2.0mm
SLV NP353 Ø3.8 3.0mm

Anatomic 15° Straight Abutment | Regular

Code Platform Diameters Gingival Height (H)
SLV RP354 Ø4.7 1.0mm
SLV RP355 Ø4.7 2.0mm
SLV RP356 Ø4.7 3.0mm

Anatomic 15° Straight Abutment | Wide

Code Platform Diameters Gingival Height (H)
SLV WP357 Ø5.7 1.0mm
SLV WP358 Ø5.7 2.0mm
SLV WP359 Ø5.7 3.0mm

Anatomic 25° Straight Abutment​ | Narrow

Code Platform Diameters Gingival Height (H)
SLV NP360 Ø3.8 1.0mm
SLV NP361 Ø3.8 2.0mm
SLV NP362 Ø3.8 3.0mm

Anatomic 25° Straight Abutment​ | Regular

Code Platform Diameters Gingival Height (H)
SLV RP363 Ø4.7 1.0mm
SLV RP364 Ø4.7 2.0mm
SLV RP365 Ø4.7 3.0mm

Anatomic 25° Straight Abutment​ | Wide

Code Platform Diameters Gingival Height (H)
SLV WP366 Ø5.7 1.0mm
SLV WP367 Ø5.7 2.0mm
SLV WP368 Ø5.7 3.0mm

Ti-Base Casting Abutment | HEX

Code Platform Diameters Gingival Height (H)
SLV 30850 Ø4.2 0.8mm

Ti-Base Casting Abutment | NO-HEX

Code Platform Diameters Gingival Height (H)
SLV 30851 Ø4.2 0.8mm
Burn-Out Cap
SL 30903
Abutment Screw
SLV 16000

Universal Straight Abutment

Code Platform Diameters Gingival Height (H)
SLV NP001 Ø4.0 2.0mm
SLV RP002 Ø4.7 2.0mm
SLV WP003 Ø5.8 2.0mm

Closed Tray | HEX

Code Platform Diameter Gingival Height (H)
SLV 30100 Ø4.0 2.5mm
SLV 30102 Ø4.8 2.5mm

Closed Tray | NO-HEX

Code Platform Diameter Gingival Height (H)
SLV 30101 Ø4.0 2.5mm
SLV 30103 Ø4.8 2.5mm

Closed Tray Impression Parts are packed wtih SLV 16006 screw.

Impression Part Ø4.5 (HEX)
SLV 30112
Impression Part Ø4.5 (NO-HEX)
SLV 30113
Closed Tray Screw
SLV 16004

0° Multi Unit Abutment | HEX

Code Platform Diameters Gingival Height (H)
SLV 30501 Ø5.0 1.0mm
SLV 30502 Ø5.0 2.0mm
SLV 30503 Ø5.0 3.0mm
SLV 30504 Ø5.0 4.0mm
SLV 30505 Ø5.0 5.0mm

0° Multi Unit Abutment | NO-HEX

Code Platform Diameters Gingival Height (H)
SLV 30506 Ø5.0 1.0mm
SLV 30507 Ø5.0 2.0mm
SLV 30508 Ø5.0 3.0mm
SLV 30509 Ø5.0 4.0mm
SLV 30510 Ø5.0 5.0mm

15° Multi Unit Abutment

Code Platform Diameters Gingival Height (H)
SLV 30511 Ø5.0 0.9mm / 2.2mm
SLV 30512 Ø5.0 1.8mm / 3.2mm
SLV 30513 Ø5.0 2.8mm / 4.2mm

30° Multi Unit Abutment

Code Platform Diameters Gingival Height (H)
SLV 30514 Ø5.0 2.0mm / 2.5mm
SLV 30515 Ø5.0 3.0mm / 3.5mm
SLV 30516 Ø5.0 4.0mm / 4.5mm

Temporary Abutment | HEX

Code Platform Diameters Gingival Height (H)
SLV 30651 Ø4.7 1.0mm
SLV 30653 Ø4.7 1.0mm

Temporary Abutment | NO-HEX

Code Platform Diameters Gingival Height (H)
SLV 30652 Ø4.7 1.0mm
SLV 30654 Ø4.7 1.0mm

Venuscon temporary abutment are made of Titanium Ti6Al4V ELI (Grade 23) and PEEK material for easy shapping. Available with HEX and NO-HEX options.

Ti-Base Cad-Cam Abutment | HEX

Code Platform Diameters Gingival Height (H)
SLV 30801 Ø3.8 1.0mm
SLV 30802 Ø3.8 2.0mm
SLV 30803 Ø3.8 3.0mm
SLV 30804 Ø4.7 1.0mm
SLV 30805 Ø4.7 2.0mm
SLV 30806 Ø4.7 3.0mm

Ti-Base Cad-Cam Abutment | NO-HEX

Code Platform Diameters Gingival Height (H)
SLV 30808 Ø3.8 1.0mm
SLV 30809 Ø3.8 2.0mm
SLV 30810 Ø3.8 3.0mm
SLV 30811 Ø4.7 1.0mm
SLV 30812 Ø4.7 2.0mm
SLV 30813 Ø4.7 3.0mm

Sirona Ti-Base Abutment

Code Platform Diameters Gingival Height (H)
SLV 30807 Ø4.5 1.0mm
Scanning Part
SLV 30900
Premill Abutment
SLV P3000
Digital Analog
SLV 30202

Locator Abutment

Code Platform Diameters Gingival Height (H)
SLV 30451 Ø3.86 1.0mm
SLV 30452 Ø3.86 2.0mm
SLV 30453 Ø3.86 3.0mm
SLV 30454 Ø3.86 4.0mm
SLV 30455 Ø3.86 5.0mm

Ball Abutment

Code Platform Diameters Gingival Height (H)
SLV 30601 Ø4.5 1.0mm
SLV 30602 Ø4.5 2.0mm
SLV 30603 Ø4.5 3.0mm
SLV 30604 Ø4.5 4.0mm
SLV 30605 Ø4.5 5.0mm
Metal Ring
SL 30905
Transparent Ring Cap
SRF 083
Ball Analog
SL 30203
Locator Analog
SL 30204

Narrow

Code Platform Diameters Gingival Height (H)
SLV NP101 Ø3.9 2.0mm
SLV NP102 Ø3.9 4.0mm
SLV NP103 Ø3.9 6.0mm

Regular

Code Platform Diameters Gingival Height (H)
SLV RP104 Ø4.8 2.0mm
SLV RP105 Ø4.8 4.0mm
SLV RP106 Ø4.8 6.0mm

Wide

Code Platform Diameters Gingival Height (H)
SLV WP107 Ø5.8 2.0mm
SLV WP108 Ø5.8 4.0mm
SLV WP109 Ø5.8 6.0mm

Narrow

Code Platform Diameters Gingival Height (H)
SLV NP110 Ø3.9 4.0mm
SLV NP111 Ø3.9 6.0mm

Regular

Code Platform Diameters Gingival Height (H)
SLV RP112 Ø4.8 4.0mm
SLV RP113 Ø4.8 6.0mm

Wide

Code Platform Diameters Gingival Height (H)
SLV WP114 Ø5.8 4.0mm
SLV WP115 Ø5.8 6.0mm

Ti-Base

Code Platform Diameters Gingival Height (H)
SLV 30119 Ø4.0 6.0mm
SLV 30120 Ø4.8 6.0mm

PEEK

Code Platform Diameters Gingival Height (H)
SLV 30121 Ø5.8 6.0mm
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.